PRODUCTS
Conductivity Meters
EM31-MK2
EM34-3
EM38-MK2
Metal Detectors
Time Domain Systems
VLF Systems
Borehole Probes
Data Acquisition
Software
Third Party Software
Downloads

EM34-3 | EM34-3XL

EM34-3

The EM34-3 is a simple-to-operate, cost-effective instrument for the geologist and hydrogeologist alike; applications have been particularly successful for the mapping of deeper groundwater contaminant plumes and for the exploration of potable groundwater resources.

Using the same inductive method as the EM31-MK2, the EM34-3 uses three intercoil spacings - 10, 20 and 40 m - to provide variable depths of exploration down to 60 metres. With three intercoil spacings and two dipole modes (horizontal as shown, and vertical) at each spacing, vertical soundings can be obtained. In the vertical dipole (horizontal coplanar) mode, the EM34-3 is very sensitive to vertical geologic anomalies and, as a consequence, is widely used for groundwater exploration in fractured and faulted bedrock.

The EM34-3 includes connectors for an analog signal output, as well as an input which can be used with a rechargeable battery option. Digital signal output, required for data collection with the DL600/DAS70 system, is available as an option for all models of the EM34-3.

EM34-3XL

In regions of particularly high cultural and/or atmospheric noise, the EM34-3XL - including increased transmitter power and a larger transmitter coil - improves the signal-to-noise ratio by a factor of 10 at the 40 m spacing, and by a factor of 4 at the 10 and 20 m spacings.


Specifications
MEASURED QUANTITIES
  Apparent conductivity in millisiemens per metre (mS/m)
PRIMARY FIELD SOURCE
Self-contained dipole transmitter
SENSOR
Self-contained dipole receiver
REFERENCE CABLE
Lightweight, 2 wire shielded cable
INTERCOIL SPACINGS &
OPERATING FREQUENCY
10 m at 6.4 kHz
20 m at 1.6 kHz
40 m at 0.4 kHz
POWER SUPPLY
Transmitter: 8 disposable or rechargeable “D” cells
Receiver: 8 disposable or rechargeable “C” cells
CONDUCTIVITY RANGES
Conductivity: 10, 100, 1k mS/m
MEASUREMENT RESOLUTION
+/- 0.1% of full scale
MEASUREMENT ACCURACY
+/- 5% at 20 mS/m
NOISE LEVELS
Conductivity: 0.2 mS/m (can be greater in regions of high power line interference)
DIMENSIONS
Rx Console: 19x13.5x26 cm
Tx Console: 15.5x8x26 cm
Rx & Tx Coil: 63 cm diameter
EM34-3XL Tx Coil: 100 cm
Case: 27.5x75x75 cm
WEIGHTS
Instrument: 20.5 kg; XL: 26.5 kg
Shipping: 43 kg; XL: 51 kg

 
             
Copyright  ©  2013 Geonics Limited. All rights reserved