PRODUCTS
Conductivity Meters
Metal Detectors
Time Domain Systems
PROTEM Receiver
TEM47
TEM57-MK2
TEM67
PROTEM CM
G-TEM
Surface Sensors
VLF Systems
Borehole Probes
Data Acquisition
Software
Third Party Software
Downloads

PROTEM CM

By consolidating the PROTEM receiver and TEM47 transmitter components into a single console, the PROTEM CM system offers significant improvements in portability and convenience: As compared to the individual receiver and transmitter components, the PROTEM CM is both smaller in size, and less in weight by about half. The increase in component portability will be of particular benefit for surveys in more demanding environments, both in-mine and over rugged terrain.

Available with cable reference synchronization only, for either single component or sequential three-component data collection, PROTEM CM otherwise offers the same functions and performance characteristics as the standard PROTEM 47 components, and is compatible with all other Geonics transmitters.

For greater depth of exploration, a high power (HP) modification to increase the output current from the transmitter section is available as an option.


Specifications
RECEIVER SECTION
MEASURED QUANTITIES
Rate of decay of induced magnetic field along 3 axes
TIME GATES
20 or 30 geometrically spaced gates for each base frequency, range from 6 μs to 800 ms
BASE FREQUENCY
0.3, 0.75, 3, 7.5, 30, 75, 285 Hz, or
0.25, 0.625, 2.5, 6.25, 25, 62.5, 237.5 Hz
DYNAMIC RANGE
29 bits (175 dB) including all gains
SYNCHRONIZATION
Internal terminals provided for cable reference with external transmitters
DATA OUTPUT
RS-232 serial, USB ports
TRANSMITTER SECTION
CURRENT WAVEFORM
Bipolar rectangular current with 50% duty cycle
BASE FREQUENCY
30, 75, or 285 Hz (60 Hz power line frequency)
25, 62.5, or 237.5 Hz (50 Hz power line frequency)
TURN-OFF TIME
2.5 μs at 2 A into 40 x 40 m loop; faster into smaller loop
TRANSMITTER LOOP
Any dimension from 5 x 5 m to 200 x 200 m; multiple-turn loops possible, from 1 x 1 m
OUTPUT VOLTAGE
CM: 0 to 9 V continuously adjustable (at 1 A load), or 24 V
CM HP: 12 to 36 V with external batteries
OUTPUT CURRENT
CM: 3.5 A maximum (7 A pp) with internal battery
CM HP: 11 A maximum (22 A pp) with external batteries
GENERAL
POWER SOURCE
Internal 12/24 V rechargeable lithium-ion battery
BATTERY LIFE
8 h continuous operation with 2 A transmitter current at 12 V output voltage
OPERATING TEMPERATURE
-30°C to +50°C
DIMENSIONS
40 x 35 x 24 cm
WEIGHT
CM: 10.5 kg; CM HP: 11.7 kg

 
             